< Back to Case Studies

Integrated energy management for the hospitality sector

Industry: Hospitality

  • Integrated energy source management
  • Cost-optimised CHP operation
  • Reduced energy consumption in high-demand areas
  • Dynamic load management

 challenge

Hubertus needed a clearer understanding of how energy generation, demand and consumption affected the hotel’s operations. A key priority was to assess the performance of its CHP units and other energy sources against actual demand, while gaining detailed visibility into energy consumption across operational areas and energy-intensive equipment to identify hidden inefficiencies and optimisation opportunities.

 solution

Hubertus implemented E‑BOOST to centralise energy monitoring and provide an integrated view of energy generation, demand and equipment performance. Continuous data analysis supports operational decisions through:

  • Energy source integration: Data from CHP units, photovoltaic systems, pellet boilers, the grid and major electrical loads are consolidated to analyse how energy is generated and consumed across the hotel.
  • Inefficiency and anomaly detection: Consumption profiles, operating conditions and equipment behaviour are correlated to identify deviations, anomalies and suboptimal operating conditions.
  • Granular load visibility: Energy consumption is analysed at individual area and equipment level, providing detailed insights into load profiles and usage patterns.

 impact

Hubertus moved from managing individual systems separately to coordinating energy assets based on actual demand, revealing optimisation opportunities that were previously difficult to identify.

Between 2024 and 2025, the hotel also recorded a 3.15% reduction in electricity consumption, equivalent to 8,233 kWh, driven by a combination of operational improvements and increased on-site energy self-consumption.

Zero-investment optimisations

  • Optimised CHP operation: Aligning electricity and heat generation with actual demand and energy costs, with potential savings of up to €3,000/year, depending on market prices.
  • Hotel load optimisation: Identifying unnecessary consumption and adjusting the operation of kitchens, SPA facilities, saunas and pools to actual usage. The kitchen, accounting for 59% of monitored electricity consumption, offers potential overnight savings of 9,500 kWh/year (approximately €2,000/year).
  • Anomaly monitoring: Detecting abnormal vibrations in CHP units and operating deviations in other equipment to support maintenance decisions and reduce the risk of unplanned downtime.

Low-investment optimisations

  • Equipment efficiency: Adjusting kitchen and SPA ventilation through variable frequency drives (VFDs), with estimated savings exceeding €2,000/year, and integrating an auxiliary heat pump to optimise CHP operation according to electricity and heat demand.

−0%

Estimated reduction in electricity consumption

€0/year

Estimated annual cost savings